SM OSW Module 4 (2≤N≤128)
MEMS 1xN OSW is based on micro-electro-mechanical system technology. It allows channel selection between an input fiber and up to N output fibers by rotating the MEMS mirror. The switch is bi-directional and can also be used as a Nx1 selector switch. The optical switch offers highly reliable, durable, long-life operation in a compact package.
Features
Proven MEMS durability and reliability
Compact Form Factor
Fast switching time
Qualified to Telcordia GR-1073-CORE and RoHS requirements
UART/TTL or TTL parallel control interface
Applications
Fiber monitoring (Working with OTDR or OCM)
Optical network routing
Fiber sensing
Resource sharing
Optical network protection and restoration
Optical Specifications
PARAMETER | VALUE | UNIT | NOTE | |
|---|---|---|---|---|
Wavelength |
13:1290~1330 | nm |
@Single-band: 13 or 15 or 16 | |
Test Wavelength | 1310/1550/1625 or 1650 | nm | ||
OSW Channels | 2~128 | N | ||
Insertion Loss | 1x2 | ≤0.7, typical 0.5 | dB |
@CWL,23°C
≤64, single stage |
1x4 | ≤0.8, typical 0.6 | |||
1x8 | ||||
1x12 | ≤1.0, typical 0.9 | |||
1x16 | ||||
1x24 | ≤1.3, typical 1.1 | |||
1x32 | ||||
1x48 | ≤1.5, typical 1.2 | |||
1x64 | ||||
1x96 | ≤2.0, typical 1.8 | |||
1x128 | ||||
Return Loss | ≥45 | dB | Or customer specify | |
Repeatability | ≤0. 1 | dB | Repeatability is defined after 100 cycles | |
Crosstalk | ≥40 | dB | Or customer specify | |
Polarization Dependence Loss | ≤0.2 | dB | ||
Wavelength Dependence Loss | ≤0.3 @S | dB | @CWL±20nm, 23°C | |
Temperature Dependence Loss |
≤0.3 @N≤16 | dB | TDL is for single-band | |
Switch Time |
≤15 @N≤64 | ms | Or customer specify | |
Durability | ≥1x109 | cycle | ||
Maximum Optical Power | ≤500 | mW | ||
Electrical and Mechanical Specification
PARAMETER | VALUE | UNIT | NOTE |
|---|---|---|---|
Switch Mode | Non-latching | ||
Control Voltage | 5±0.25 | V | Module type |
Dimension | 80x60x16 | mm |
M4, single stage, 2 |
80x60x22 |
M4, double stage, 64 |
Environmental conditions
PARAMETER | VALUE | UNIT | NOTE |
|---|---|---|---|
Operation Temperature | -5~65 | °C | |
Storage Temperature | -40~85 | °C | |
Operation Humidity | 5~95 | %RH | |
Storage Humidity | 5~95 | %RH |